====Method==== The **objects/history** endpoint supports the non-standard **method** parameter in [[i3x:Welcome|i3X]]. This is combined with the [[resolution_samples|resolution / samples]] parameter to control the information returned when asking for history. The choice for //method// are... **raw** - Results are returned at their native resolution. WARNING: in some data sources, resolution can be in excess of 20-samples-per-second. **interp** (the default) - Results are broken into small time windows, and the average is returned in each window. This is extremely useful for charts or calculations, but may miss extremely fine details. **min** - Shows the minimum value for each time-window. Useful for picking up any very small outages or issues. **max** - Shows the maximum value for each time-window. Useful for picking up surges or other extremely brief issues. The default mode can be changed in [[i3X Settings|i3X settings]].